I/O Modules

Q.brixx A101

2 universal analog input channels

voltage, current, resistance, potentiometer, Pt100, Pt1000, thermocouples, measuring bridges, IEPE sensors

Fast high accuracy digitalization

24 bit ADC, 100 kHz sample rate per channel

1 digital in or output per channel

input: state, tare, memory reset

output: state alarm, threshold

Signal conditioning

16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm

Galvanic isolation

of I/O-signals, power supply and interface Isolation voltage 500 VDC

Q.brixx A102

1 analog input channel

measuring bridge (full, half, quarter), IEPE-sensors, voltage, current

1 analog output

voltage ±10 V and current 0 up to 25 mA selectable, 100 kHz

Fast high accuracy digitalization

19 Bit ADC - SAR (without delay time), 100 kHz sample rate

4 digital inputs, 2 digital outputs

input: state, tare, memory reset

output: state alarm, thresh hold

Signal conditioning

16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm

Galvanic isolation

of I/O-signals, power supply and interface Isolation voltage 500 VDC

Q.brixx A103

8 galvanic isolated input channels

differential voltage, current via shunt connector Isolation voltage 100 VDC

High accuracy digitalization

24 bit ADC, 100 Hz sample rate per channel with 8 active channels, 100 Hz sample rate per channel

2 digital in and 2 outputs

input: state, tare, memory reset

output: state alarm, thresh hold

Signal conditioning

linearization, digital filter, average, scaling, min/max storage, arithmetic, alarm

Galvanic isolation

of I/O-signals, power supply and interface Isolation voltage 500 VDC

Accuracy class 0.01

Q.brixx A104

8 galvanic isolated input channels

thermocouples and voltages in the range of ±80 mV Isolation voltage 100 VDC

Cold junction compensation

good thermal coupling by means of cold junction compensation per connector

Dynamic linearization

optimized positioning of the interpolation points within the selected range, type B, E, J, K, L, N, R, S, T, U

High accuracy digitalization

24 bit ADC, 100 Hz sample rate per channel with 8 active channels, 100 Hz sample rate per channel

Signal conditioning

digital filter, average, scaling, min/max storage, arithmetic, alarm

Galvanic isolation

of I/O-signals, power supply and interface Isolation voltage 500 VDC

Accuracy class 0,01

Q.brixx A105

High accuracy

Deviation max. 0.05°C, Temperature influence 0.02/10K

4 input channels

Pt100 or resistance in 3- or 4- wire technique

High accuracy digitalization

24 bit ADC, 10 Hz sample rate per channel

Signal conditioning

linearization, digital filter, average, scaling, min/max storage, arithmetic, alarm

Galvanic isolation

channel to channel to power supply and to interface Isolation voltage 500 VDC

Q.brixx A106

2 analog input channels

Strain gage and inductive measuring bridges (full, half, quarter), LVDT, RVDT

DC and carrier frequency (CF) principle

DC excitation, 600 Hz CF excitation, 4.8 kHz CF excitation for bridges

1 analog output per channel

Voltage ±10 V, 10 kHz

Fast high accuracy digitalization

24 bit ADC, 10 kHz sample rate per channel

1 digital in or output per channel

input: state, tare, memory reset

output: state alarm, thresh hold

Signal conditioning

16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm

Galvanic isolation

of I/O-signals, power supply and interface Isolation voltage 500 VDC

Q.brixx A107

4 universal analog input channels

voltage, current, resistance, potentiometer, Pt100, Pt1000, thermocouples, measuring bridges

Fast high accuracy digitalization

24 bit ADC, 10 kHz sample rate per channel

Signal conditioning

16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm

Galvanic isolation

of I/O-signals, power supply and interface

Q.brixx A108

8 galvanic isolated input channels

differential voltage, current via shunt connector Isolation voltage 100 VDC

Fast high accuracy digitalization

24 bit ADC, 10 kHz sample rate per channel with 8 active channels

2 digital in and 2 outputs

input: state, tare, memory reset

output: state alarm, thresh hold

Signal conditioning

linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm

Galvanic isolation

of I/O-signals, power supply and interface Isolation voltage 500 VDC

Accuracy class 0,01

Q.brixx A109

4 galvanic isolated analog output channels

voltage ±10 V, current 4…20 mA selectable Isolation voltage 500 VDC

DAC-resolution 16 bit

100 kHz with 1 channel, 10 kHz with 4 channels

4 digital inputs and 4 digital outputs

configurable as 2 counter, 2 frequency, or 2 PWM inputs, 2 frequency or PWM output, state in or output

Frequency in and outputs

frequency measurement up to 1 MHz (Chronos method), frequency output up to 10 kHz

Counter

For/backward counter, quadrature counter with reference zero recognition (reset/enable), up to 1 MHz

PWM in and output

measurement of duty cycle and frequency, output with variable frequency and/or duty cycle

Outputs freely scalable

Galvanic isolation

of I/O-signals, power supply and interface Isolation voltage 500 VDC

Q.brixx A111

4 galvanic isolated analog input channelsIEPE sensors, voltagesFast high accuracy digitalization

24 bit ADC, 100 kHz sample rate per channel

Signal conditioning

16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm

Galvanic isolation

channel to channel to power supply and to interface isolation voltage 500 VDC

Q.brixx A116

8 analog input channels for bridges

strain gauge bridges (full, half, quarter), 8 real parallel inputs, neither scanned nor multiplexed

Flexible Input

DC bridge excitation 2 V and 4 V input range 1 mV/V and 5 mV/V

Fast high accuracy digitalization

24 bit ADC, 10 kHz sample rate per channel

Signal conditioning

linearization, digital filter, average, scaling, min/max storage, arithmetic, alarm

Shunt calibration signal per channel

Compatible with all Q.series modules

e.g. for displacement, temperature, counter, voltage, current, resistance, frequency, I/O

Galvanic isolation

channel to power supply and to interface Isolation voltage 500 VDC

Q.brixx A123

4 galvanically isolated input channels

Voltages at high potential, ranges 100 mV, 1 V, 10 V

Insulation voltage 1200 VDC

short-term 5000 VDC

Fast high accuracy digitalization

24 bit ADC, 50 kHz sample rate per channel with 4 channels, 100 kHz sample rate per channel with 2 channels

Signal conditioning

16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm

Q.brixx A124

4 galvanically isolated input channels

for non-insulated thermocouples at high potential

Insulation voltage 1200 VDC

short-term 5000 VDC

Cold junction compensation

Dynamic linearization

Optimum positioning of interpolation points in selected range, types B, E, J, K, L, N, R, S, T, U

High accuracy digitalization

24 bit ADC, 10 kHz sample rate per channel

Signal conditioning

digital filter, average, scaling, min/max storage, arithmetic, alarm

Q.brixx A127

4 voltage input channels

2 inputs for voltage measurement measuring ranges ±40 V, ±120 V, ±400 V, ±1200 V

2 inputs for current measurement via shunt resistors measuring ranges ±80 mV, ±240 mV, ±800 mV, ±2400 mV

Fast high accuracy digitalization

24 bit ADC, 50 kHz sample rate per channel with 4 channels, 100 kHz sample rate per channel with 2 channels

Signal conditioning

linearization, digital filter, average, scaling, min/max storage, RMS, alarm

Galvanic isolation

channel to channel to power supply and to interface isolation voltage 1200 VDC / 858 VACrms test voltage 5 kVDC over 1 minute

Q.brixx A128

4 galvanically isolated input channels

Voltages, ranges 40 V, 120 V, 400 V, 1200 V

Insulation voltage 1200 VDC

short-term 5000 VDC

Fast high accuracy digitalization

24 bit ADC, 50 kHz sample rate per channel with 4 channels, 100 kHz sample rate per channel with 2 channels

Signal conditioning

16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm

Q.brixx D101

8 digital inputs and 8 digital outputs

configurable as counter, frequency, PWM and time inputs, frequency or PWM output, state in or output

State in and outputs

process- and host controlled

Frequency in and outputs

frequency measurement up to 1 MHz (Chronos method), frequency output up to 10 kHz

Counter

for/backward counter, quadrature counter with reference zero recognition (reset/enable), up to 1 MHz

PWM in and outputs

measurement of duty cycle and frequency, output with variable frequency and/or duty cycle

Time measurement

Q.brixx D104

16 digital inputs

state, single or bit set, host controlled

Configurable threshold

TTL or high level (EN61131-2, Type1)

Short reaction time

10 µs per input

Galvanic isolation

of I/O-signals (2 groups x 8 inputs), to power supply and to interface Isolation voltage 500 VDC

Q.brixx D105

16 digital outputs

state, single or bit set, host controlled

High possible load

30 VDC / 500 mA short circuit proof

Short reaction time

10 µs up to 1 ms per input

Galvanic isolation

of I/O-signals (2 groups x 8 inputs), to power supply and to interface Isolation voltage 500 VDC

Q.brixx D107

6 configurable digital inputs

2 channels, each 3 differential or single-ended, frequency, counter, PWM, state

Adjustable threshold in 256 steps

Differential inputs in the range of -20 V up to + 20 V, Single-ended inputs in the range of 0 V up to +26 V

Frequency inputs

Frequency measurement up to 1 MHz (Chronos method), direction recognition

Counter

Up/down counter, quadrature counter with reference zero, up to 1 MHz

PWM inputs

Measurement of duty cycle and frequency, output with variable frequency and/or duty cycle

Galvanic isolation

Terminal 1, Terminal 2, power supply and interface Isolation voltage 500 VDC

Q.brixx S104

4 galvanic isolated voltages

+5 VDC, +12 VDC, +15 VDC, +24 VDC

High possible load

each voltage is loadable with 5 W

Combinations are possible

voltages can be connected to get combinations like 17 V or 20 V

Galvanic isolation

each voltage is galvanic isolated with 1.5 kV

back